{"product_id":"ammeter-sensor","title":"Ammeter Sensor","description":"\u003cdiv class=\"flybox-dbmisensc-wrapper\" style=\"font-family: inherit; line-height: 1.85; color: #1e293b; font-size: 1.25rem;\"\u003e\n\n  \u003c!-- Hero Header Panel --\u003e\n  \u003cdiv style=\"background: linear-gradient(135deg, #0C1B2A 0%, #1e293b 100%); color: #ffffff; padding: 2.75rem 2.25rem; border-radius: 12px; margin-bottom: 2.75rem; box-shadow: 0 4px 12px rgba(12, 27, 42, 0.15);\"\u003e\n    \u003cdiv style=\"font-size: 1.05rem; font-weight: 800; letter-spacing: 2px; text-transform: uppercase; color: #38bdf8; margin-bottom: 0.75rem;\"\u003e\n      Genuine Flybox Avionics Sensor\n    \u003c\/div\u003e\n    \u003ch2 style=\"font-size: 2rem; font-weight: 700; margin: 0 0 1.35rem 0; color: #ffffff; line-height: 1.3;\"\u003e\n      Flybox ±50A Ammeter Current Sensor (DBMISENSC)\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size: 1.3rem; color: #e2e8f0; margin: 0; line-height: 1.75;\"\u003e\n      The \u003cstrong\u003eFlybox DBMISENSC\u003c\/strong\u003e is a high-precision, solid-state Hall-effect current sensor engineered for \u003cstrong\u003eUltralight, Light Sport (LSA), and Experimental aircraft\u003c\/strong\u003e. Designed to measure bidirectional DC electrical flow across \u003cstrong\u003e-50 A to +50 A\u003c\/strong\u003e, it replaces traditional resistive shunts with a galvanically isolated, zero-insertion-loss solution that feeds real-time battery charge\/discharge and alternator current directly to Flybox glass cockpit displays.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Key Specs Dashboard Strip --\u003e\n  \u003cdiv style=\"background-color: #f8fafc; border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; margin-bottom: 3rem; display: flex; flex-wrap: wrap; justify-content: space-between; gap: 1.5rem;\"\u003e\n    \u003cdiv style=\"flex: 1 1 220px;\"\u003e\n      \u003cspan style=\"display: block; font-size: 1rem; font-weight: 800; color: #64748b; text-transform: uppercase;\"\u003ePart Number\u003c\/span\u003e\n      \u003cspan style=\"font-size: 1.35rem; font-weight: 700; color: #0C1B2A;\"\u003eDBMISENSC\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1 1 220px;\"\u003e\n      \u003cspan style=\"display: block; font-size: 1rem; font-weight: 800; color: #64748b; text-transform: uppercase;\"\u003eMeasuring Range\u003c\/span\u003e\n      \u003cspan style=\"font-size: 1.35rem; font-weight: 700; color: #0C1B2A;\"\u003e±50 A DC\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1 1 220px;\"\u003e\n      \u003cspan style=\"display: block; font-size: 1rem; font-weight: 800; color: #64748b; text-transform: uppercase;\"\u003eSensing Type\u003c\/span\u003e\n      \u003cspan style=\"font-size: 1.35rem; font-weight: 700; color: #0C1B2A;\"\u003eHall-Effect Solid State\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1 1 220px;\"\u003e\n      \u003cspan style=\"display: block; font-size: 1rem; font-weight: 800; color: #64748b; text-transform: uppercase;\"\u003eSupply Voltage\u003c\/span\u003e\n      \u003cspan style=\"font-size: 1.35rem; font-weight: 700; color: #0C1B2A;\"\u003e+5 V DC (Instrument)\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section: Core Capabilities (2x2 Grid) --\u003e\n  \u003ch3 style=\"font-size: 1.55rem; color: #0C1B2A; text-transform: uppercase; letter-spacing: 1px; margin-bottom: 0.75rem; font-weight: 700;\"\u003e\n    Operational Capabilities \u0026amp; Electrical Bus Safety\n  \u003c\/h3\u003e\n  \u003cp style=\"font-size: 1.25rem; color: #475569; margin: 0 0 2rem 0;\"\u003e\n    Advanced current monitoring engineered for modern light aircraft electrical systems:\n  \u003c\/p\u003e\n\n  \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(320px, 1fr)); gap: 1.75rem; margin-bottom: 3rem;\"\u003e\n    \n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 4px solid #0C1B2A;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.85rem;\"\u003e\n        \u003cspan style=\"background: #0C1B2A; color: #ffffff; width: 32px; height: 32px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-size: 0.95rem; font-weight: 700; margin-right: 12px;\"\u003e01\u003c\/span\u003e\n        \u003ch4 style=\"margin: 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eTrue Bidirectional Monitoring\u003c\/h4\u003e\n      \u003c\/div\u003e\n      \u003cp style=\"margin: 0; font-size: 1.18rem; color: #334155; line-height: 1.75;\"\u003e\n        Accurately monitors both positive charging currents and negative battery discharge rates across ±50 A, immediately highlighting alternator drops or excessive in-flight electrical demand.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 4px solid #0C1B2A;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.85rem;\"\u003e\n        \u003cspan style=\"background: #0C1B2A; color: #ffffff; width: 32px; height: 32px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-size: 0.95rem; font-weight: 700; margin-right: 12px;\"\u003e02\u003c\/span\u003e\n        \u003ch4 style=\"margin: 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eFull Galvanic Isolation\u003c\/h4\u003e\n      \u003c\/div\u003e\n      \u003cp style=\"margin: 0; font-size: 1.18rem; color: #334155; line-height: 1.75;\"\u003e\n        Electrically isolates high-current main aircraft bus cables from sensitive instrument logic circuits, eliminating short-circuit hazards and ground-loop offsets without high-voltage risks.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 4px solid #0C1B2A;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.85rem;\"\u003e\n        \u003cspan style=\"background: #0C1B2A; color: #ffffff; width: 32px; height: 32px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-size: 0.95rem; font-weight: 700; margin-right: 12px;\"\u003e03\u003c\/span\u003e\n        \u003ch4 style=\"margin: 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eZero Heat \u0026amp; Resistance Drop\u003c\/h4\u003e\n      \u003c\/div\u003e\n      \u003cp style=\"margin: 0; font-size: 1.18rem; color: #334155; line-height: 1.75;\"\u003e\n        Unlike resistive brass shunts that generate thermal dissipation and drop line voltage, the non-intrusive magnetic Hall-effect core introduces virtually zero electrical resistance into the bus.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 4px solid #0C1B2A;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.85rem;\"\u003e\n        \u003cspan style=\"background: #0C1B2A; color: #ffffff; width: 32px; height: 32px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-size: 0.95rem; font-weight: 700; margin-right: 12px;\"\u003e04\u003c\/span\u003e\n        \u003ch4 style=\"margin: 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eLinear Signal Integrity\u003c\/h4\u003e\n      \u003c\/div\u003e\n      \u003cp style=\"margin: 0; font-size: 1.18rem; color: #334155; line-height: 1.75;\"\u003e\n        Outputs a robust, linear analogue voltage signal directly compatible with Flybox display ammeter inputs, avoiding the low-millivolt noise distortion that plagues traditional shunt installations.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003chr style=\"border: 0; border-top: 1px solid #cbd5e1; margin: 3.5rem 0;\"\u003e\n\n  \u003c!-- Technical Specifications Table --\u003e\n  \u003ch3 style=\"font-size: 1.55rem; color: #0C1B2A; text-transform: uppercase; letter-spacing: 1px; margin-bottom: 2rem; display: flex; align-items: center; font-weight: 700;\"\u003e\n    \u003cspan style=\"display: inline-block; width: 14px; height: 14px; background-color: #0C1B2A; border-radius: 50%; margin-right: 14px;\"\u003e\u003c\/span\u003e\n    Technical Specifications\n  \u003c\/h3\u003e\n  \n  \u003cdiv style=\"overflow-x: auto; border: 1px solid #cbd5e1; border-radius: 8px; margin-bottom: 2.25rem;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 1.2rem; line-height: 1.7;\"\u003e\n      \u003ctbody\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A; width: 44%;\"\u003eManufacturer Part Number\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eDBMISENSC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eProduct Function\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eSolid-State DC Ammeter Current Sensor\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eMeasuring Range\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003e-50 A to +50 A DC (Bidirectional charge\/discharge)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eSensing Architecture\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eLinear solid-state Hall-effect magnetic transducer\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eSignal Output\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eLinear analogue voltage proportional to primary current\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eOperating Voltage Supply\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003e+5 V DC regulated (supplied directly from Flybox instrument)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eGalvanic Isolation\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eComplete electrical isolation between high-current path and sensor output\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eFlight Instrument Compatibility\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eFlybox Omnia AMP-VOLT (57 mm \u0026amp; 80 mm), Vigilus EIS, EngiMaster EIS, Eclipse NG\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eOperating Temperature Range\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003e-20°C to +85°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eTarget Aircraft\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eUltralights, Light Sport (LSA), Microlights, and Homebuilt Experimental aircraft\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Operational Note Callout --\u003e\n  \u003cdiv style=\"background-color: #f1f5f9; border-left: 6px solid #0C1B2A; padding: 1.75rem 2rem; border-radius: 4px; font-size: 1.18rem; color: #334155; line-height: 1.8;\"\u003e\n    \u003cstrong\u003eInstallation Advisory:\u003c\/strong\u003e Mount the sensor firmly to a sub-panel or bulkhead near the main electrical bus using cushioned fasteners. Ensure the heavy-gauge bus wire passing through the sensor is securely supported with adel clamps to prevent mechanical strain on the sensor body. Connect the 3-wire signal lead (+5V, GND, Signal) to the dedicated ammeter input on your Flybox harness, and calibrate the zero-point offset in the instrument setup menu if prompted.\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Flybox Avionics","offers":[{"title":"Default Title","offer_id":59020522062155,"sku":"601060","price":72.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9719\/6363\/files\/Current_sensor.jpg?v=1793108231","url":"https:\/\/www.albionaero.co.uk\/products\/ammeter-sensor","provider":"Albion Aero Services Ltd","version":"1.0","type":"link"}