{"product_id":"omnia-fuel-pressure","title":"Omnia Fuel Pressure","description":"\u003cdiv class=\"omnia-fuelp-wrapper\" style=\"font-family: inherit; line-height: 1.85; color: #1e293b; font-size: 1.25rem;\"\u003e\n\n  \u003c!-- Hero Header Panel --\u003e\n  \u003cdiv style=\"background: linear-gradient(135deg, #0C1B2A 0%, #1e293b 100%); color: #ffffff; padding: 2.75rem 2.25rem; border-radius: 12px; margin-bottom: 2.75rem; box-shadow: 0 4px 12px rgba(12, 27, 42, 0.15);\"\u003e\n    \u003cdiv style=\"font-size: 1.05rem; font-weight: 800; letter-spacing: 2px; text-transform: uppercase; color: #38bdf8; margin-bottom: 0.75rem;\"\u003e\n      Flybox Omnia Series Avionics\n    \u003c\/div\u003e\n    \u003ch2 style=\"font-size: 2rem; font-weight: 700; margin: 0 0 1.35rem 0; color: #ffffff; line-height: 1.3;\"\u003e\n      Flybox Omnia Fuel P (57 mm \u0026amp; 80 mm)\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size: 1.3rem; color: #e2e8f0; margin: 0; line-height: 1.75;\"\u003e\n      The \u003cstrong\u003eFlybox Omnia Fuel P\u003c\/strong\u003e is a dedicated aircraft fuel delivery pressure gauge engineered for \u003cstrong\u003eUltralight, Light Sport (LSA), and Experimental aircraft\u003c\/strong\u003e. Designed to monitor fuel feed circuits across carburetted and injected engines, it pairs a crisp graphical dial with bold digital readouts and customisable colour arcs in either \u003cstrong\u003eBar or PSI\u003c\/strong\u003e. Compatible with 0.5–4.5 V analogue pressure transducers and direct engine CAN-bus data (Rotax 912iS\/915iS and ULPower). Available in standard \u003cstrong\u003e57 mm (2-1\/4″)\u003c\/strong\u003e and \u003cstrong\u003e80 mm (3-1\/8″)\u003c\/strong\u003e round panel cutouts.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Key Specs Dashboard Strip --\u003e\n  \u003cdiv style=\"background-color: #f8fafc; border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; margin-bottom: 3rem; display: flex; flex-wrap: wrap; justify-content: space-between; gap: 1.5rem;\"\u003e\n    \u003cdiv style=\"flex: 1 1 220px;\"\u003e\n      \u003cspan style=\"display: block; font-size: 1rem; font-weight: 800; color: #64748b; text-transform: uppercase;\"\u003eForm Factors\u003c\/span\u003e\n      \u003cspan style=\"font-size: 1.35rem; font-weight: 700; color: #0C1B2A;\"\u003e57 mm \u0026amp; 80 mm Cutout\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1 1 220px;\"\u003e\n      \u003cspan style=\"display: block; font-size: 1rem; font-weight: 800; color: #64748b; text-transform: uppercase;\"\u003eSignal Interface\u003c\/span\u003e\n      \u003cspan style=\"font-size: 1.35rem; font-weight: 700; color: #0C1B2A;\"\u003e0.5–4.5 V • CAN Bus\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1 1 220px;\"\u003e\n      \u003cspan style=\"display: block; font-size: 1rem; font-weight: 800; color: #64748b; text-transform: uppercase;\"\u003eSelectable Units\u003c\/span\u003e\n      \u003cspan style=\"font-size: 1.35rem; font-weight: 700; color: #0C1B2A;\"\u003eBar or PSI Display\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1 1 220px;\"\u003e\n      \u003cspan style=\"display: block; font-size: 1rem; font-weight: 800; color: #64748b; text-transform: uppercase;\"\u003eSupply Voltage\u003c\/span\u003e\n      \u003cspan style=\"font-size: 1.35rem; font-weight: 700; color: #0C1B2A;\"\u003e10 V – 30 V DC (~1.5 W)\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section: Form Factor Comparison --\u003e\n  \u003ch3 style=\"font-size: 1.55rem; color: #0C1B2A; text-transform: uppercase; letter-spacing: 1px; margin-bottom: 0.75rem; font-weight: 700;\"\u003e\n    Choosing Your Instrument Size\n  \u003c\/h3\u003e\n  \u003cp style=\"font-size: 1.25rem; color: #475569; margin: 0 0 2rem 0;\"\u003e\n    Select the standard round aviation cutout diameter suited to your cockpit panel arrangement:\n  \u003c\/p\u003e\n\n  \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(320px, 1fr)); gap: 1.75rem; margin-bottom: 3rem;\"\u003e\n    \n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 5px solid #0C1B2A;\"\u003e\n      \u003cspan style=\"font-size: 0.85rem; font-weight: 800; color: #0C1B2A; text-transform: uppercase; letter-spacing: 1px;\"\u003eVariant 01\u003c\/span\u003e\n      \u003ch4 style=\"margin: 0.35rem 0 0.75rem 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eOmnia57 Fuel P (57 mm \/ 2-1\/4″)\u003c\/h4\u003e\n      \u003cp style=\"margin: 0; font-size: 1.15rem; color: #334155; line-height: 1.7;\"\u003e\n        The compact choice for space-constrained panels, centre pedestals, or secondary consoles. Features a 68.5 mm × 62.0 mm outer bezel, weighing only 140 g with a low 60 mA power draw. Fits standard 57 mm cutouts (57.5 mm recommended) with up to 10 mm internal screw depth.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 5px solid #0C1B2A;\"\u003e\n      \u003cspan style=\"font-size: 0.85rem; font-weight: 800; color: #0C1B2A; text-transform: uppercase; letter-spacing: 1px;\"\u003eVariant 02\u003c\/span\u003e\n      \u003ch4 style=\"margin: 0.35rem 0 0.75rem 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eOmnia80 Fuel P (80 mm \/ 3-1\/8″)\u003c\/h4\u003e\n      \u003cp style=\"margin: 0; font-size: 1.15rem; color: #334155; line-height: 1.7;\"\u003e\n        The direct drop-in replacement for traditional 3-1\/8″ round mechanical fuel pressure gauges. Features an 84.0 mm × 84.0 mm square bezel and expanded 3.5″ display area for primary flight scanning. Fits standard 80 mm cutouts (80.5 mm recommended) using M4×6mm screws (maximum 3.5 mm internal screw thread depth).\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- Section: Core Capabilities (2x2 Grid) --\u003e\n  \u003ch3 style=\"font-size: 1.55rem; color: #0C1B2A; text-transform: uppercase; letter-spacing: 1px; margin-bottom: 0.75rem; font-weight: 700;\"\u003e\n    Operational Capabilities \u0026amp; Fuel Circuit Safety\n  \u003c\/h3\u003e\n  \u003cp style=\"font-size: 1.25rem; color: #475569; margin: 0 0 2rem 0;\"\u003e\n    Precision fluid pressure tracking engineered to protect your engine from fuel delivery anomalies:\n  \u003c\/p\u003e\n\n  \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(320px, 1fr)); gap: 1.75rem; margin-bottom: 3rem;\"\u003e\n    \n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 4px solid #0C1B2A;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.85rem;\"\u003e\n        \u003cspan style=\"background: #0C1B2A; color: #ffffff; width: 32px; height: 32px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-size: 0.95rem; font-weight: 700; margin-right: 12px;\"\u003e01\u003c\/span\u003e\n        \u003ch4 style=\"margin: 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eDedicated Pressure Dial\u003c\/h4\u003e\n      \u003c\/div\u003e\n      \u003cp style=\"margin: 0; font-size: 1.18rem; color: #334155; line-height: 1.75;\"\u003e\n        Presents continuous fuel delivery line pressure using a high-visibility circular colour scale and large digital numbers. User-selectable between Bar and PSI to match your aircraft Pilot Operating Handbook (POH).\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 4px solid #0C1B2A;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.85rem;\"\u003e\n        \u003cspan style=\"background: #0C1B2A; color: #ffffff; width: 32px; height: 32px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-size: 0.95rem; font-weight: 700; margin-right: 12px;\"\u003e02\u003c\/span\u003e\n        \u003ch4 style=\"margin: 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eCustom Operational Arcs\u003c\/h4\u003e\n      \u003c\/div\u003e\n      \u003cp style=\"margin: 0; font-size: 1.18rem; color: #334155; line-height: 1.75;\"\u003e\n        Easily program low red (starvation limit), low yellow (caution), green (normal operating), high yellow, and high red (overpressure limit) bands directly via the intuitive rotary encoder knob.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 4px solid #0C1B2A;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.85rem;\"\u003e\n        \u003cspan style=\"background: #0C1B2A; color: #ffffff; width: 32px; height: 32px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-size: 0.95rem; font-weight: 700; margin-right: 12px;\"\u003e03\u003c\/span\u003e\n        \u003ch4 style=\"margin: 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eAnalogue \u0026amp; CAN-Bus Sources\u003c\/h4\u003e\n      \u003c\/div\u003e\n      \u003cp style=\"margin: 0; font-size: 1.18rem; color: #334155; line-height: 1.75;\"\u003e\n        Accepts standard 0.5–4.5 V transducers (Flybox 601041, Kavlico 15 PSI, or generic senders with custom full-scale settings) and reads digital engine CAN-bus data directly from Rotax 912iS\/915iS and ULPower powerplants.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 4px solid #0C1B2A;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.85rem;\"\u003e\n        \u003cspan style=\"background: #0C1B2A; color: #ffffff; width: 32px; height: 32px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-size: 0.95rem; font-weight: 700; margin-right: 12px;\"\u003e04\u003c\/span\u003e\n        \u003ch4 style=\"margin: 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eDual Alarms \u0026amp; Delay Timers\u003c\/h4\u003e\n      \u003c\/div\u003e\n      \u003cp style=\"margin: 0; font-size: 1.18rem; color: #334155; line-height: 1.75;\"\u003e\n        Features independent high and low visual warning banners and an NPN open-collector alarm output (300 mA). Includes programmable activation delay timers (0 to 10 seconds) to eliminate nuisance alarms during transient pump priming.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003chr style=\"border: 0; border-top: 1px solid #cbd5e1; margin: 3.5rem 0;\"\u003e\n\n  \u003c!-- Technical Specifications Table --\u003e\n  \u003ch3 style=\"font-size: 1.55rem; color: #0C1B2A; text-transform: uppercase; letter-spacing: 1px; margin-bottom: 2rem; display: flex; align-items: center; font-weight: 700;\"\u003e\n    \u003cspan style=\"display: inline-block; width: 14px; height: 14px; background-color: #0C1B2A; border-radius: 50%; margin-right: 14px;\"\u003e\u003c\/span\u003e\n    Technical Specifications\n  \u003c\/h3\u003e\n  \n  \u003cdiv style=\"overflow-x: auto; border: 1px solid #cbd5e1; border-radius: 8px; margin-bottom: 2.25rem;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 1.2rem; line-height: 1.7;\"\u003e\n      \u003ctbody\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A; width: 44%;\"\u003ePanel Cutout Compatibility\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eStandard 57 mm (2-1\/4″) or 80 mm (3-1\/8″) round aviation hole\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eDisplay Characteristics\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eHigh-brightness (1,000 nits) sunlight-readable 320×240 colour graphic TFT LCD\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eOperating Voltage Range\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003e10 V – 30 V DC (Protected against electrical bus transients)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eSupply Current Draw\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003e60 mA (Omnia57) • 135 mA (Omnia80) @ 12 V DC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eAnalogue Pressure Input\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003e1x Input channel: 0.5 V to 4.5 V signal range\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eSupported Analogue Sensors\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eFlybox 601041 (FBX), Kavlico 15 PSI (KAV15PSI), or generic 0.5–4.5 V sensors\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eDigital CAN-Bus Inputs\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eRotax 912iS, Rotax 915iS, ULPower ULP125 \u0026amp; ULP500 ECU CAN bus\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eSelectable Pressure Units\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eBar or PSI (User-configurable in menu)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eAlarm Annunciation\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eNPN open-collector (max 300 mA, active low) for warning lamp or intercom audio adapter\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eSensor Power Outputs\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eAuxiliary 12 V (500 mA) and 5 V (350 mA) short-circuit protected outputs\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eDigital Communication\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003e2x CAN-bus ports (Molex Micro-Fit) + USB 2.0 port for firmware \u0026amp; datalogging\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eHousing \u0026amp; Environmental\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eCNC-milled solid aluminium alloy • -20°C to +70°C operating temperature\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Operational Note Callout --\u003e\n  \u003cdiv style=\"background-color: #f1f5f9; border-left: 6px solid #0C1B2A; padding: 1.75rem 2rem; border-radius: 4px; font-size: 1.18rem; color: #334155; line-height: 1.8;\"\u003e\n    \u003cstrong\u003eInstallation \u0026amp; Setup Advisory:\u003c\/strong\u003e When wiring an analogue fuel pressure sensor, ensure the sensor signal ground is referenced securely to engine ground to avoid measurement offsets. If connecting to a Rotax 912iS\/915iS engine via CAN bus, the Flybox 601041 pressure sensor must still be physically plumbed into the fuel delivery rail. On Omnia80 units, ensure mounting screws do not exceed 3.5 mm thread depth inside the chassis to avoid damaging internal electronics.\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Flybox Avionics","offers":[{"title":"57mm","offer_id":58900748992843,"sku":"105764","price":423.0,"currency_code":"GBP","in_stock":true},{"title":"80mm","offer_id":58900749025611,"sku":"108064","price":480.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9719\/6363\/files\/FlyboxAvionicsOmniaFUEL-P57-80.png?v=1792413850","url":"https:\/\/www.albionaero.co.uk\/products\/omnia-fuel-pressure","provider":"Albion Aero Services Ltd","version":"1.0","type":"link"}