{"product_id":"ppg-meter","title":"PPG Meter","description":"\u003cdiv class=\"ppg-meter-manual-wrapper\" style=\"font-family: inherit; line-height: 1.85; color: #1e293b; font-size: 1.25rem;\"\u003e\n\n  \u003c!-- Hero Header Panel --\u003e\n  \u003cdiv style=\"background: linear-gradient(135deg, #0C1B2A 0%, #1e293b 100%); color: #ffffff; padding: 2.75rem 2.25rem; border-radius: 12px; margin-bottom: 2.75rem; box-shadow: 0 4px 12px rgba(12, 27, 42, 0.15);\"\u003e\n    \u003cdiv style=\"font-size: 1.05rem; font-weight: 800; letter-spacing: 2px; text-transform: uppercase; color: #38bdf8; margin-bottom: 0.75rem;\"\u003e\n      Fly Henry Precision Avionics • Model 2024\n    \u003c\/div\u003e\n    \u003ch2 style=\"font-size: 2rem; font-weight: 700; margin: 0 0 1.35rem 0; color: #ffffff; line-height: 1.3;\"\u003e\n      Fly Henry PPG Meter Engine Monitor \u0026amp; Runaway Protection System\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size: 1.3rem; color: #e2e8f0; margin: 0; line-height: 1.75;\"\u003e\n      The \u003cstrong\u003eFly Henry PPG Meter (Model 2024)\u003c\/strong\u003e is an ultra-compact, two-piece Engine Information System engineered specifically for \u003cstrong\u003ePowered Paragliding (PPG), Paramotor Trikes, and Minimalist Ultralights\u003c\/strong\u003e. Combining dual 1,200°C thermal channels, inductive RPM, and fuel computer functions, it features an automated \u003cstrong\u003eStart Monitor System\u003c\/strong\u003e that interfaces with the engine kill line to prevent startup runaways. Available \u003cstrong\u003ewith or without an external AAA battery box\u003c\/strong\u003e, and with \u003cstrong\u003ecustom cable lengths\u003c\/strong\u003e to match your chassis.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Key Specs Dashboard Strip --\u003e\n  \u003cdiv style=\"background-color: #f8fafc; border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; margin-bottom: 3rem; display: flex; flex-wrap: wrap; justify-content: space-between; gap: 1.5rem;\"\u003e\n    \u003cdiv style=\"flex: 1 1 220px;\"\u003e\n      \u003cspan style=\"display: block; font-size: 1rem; font-weight: 800; color: #64748b; text-transform: uppercase;\"\u003eDisplay Size\u003c\/span\u003e\n      \u003cspan style=\"font-size: 1.35rem; font-weight: 700; color: #0C1B2A;\"\u003e60 × 37 × 15 mm\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1 1 220px;\"\u003e\n      \u003cspan style=\"display: block; font-size: 1rem; font-weight: 800; color: #64748b; text-transform: uppercase;\"\u003ePower Supply\u003c\/span\u003e\n      \u003cspan style=\"font-size: 1.35rem; font-weight: 700; color: #0C1B2A;\"\u003e5–20V or AAA Box\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1 1 220px;\"\u003e\n      \u003cspan style=\"display: block; font-size: 1rem; font-weight: 800; color: #64748b; text-transform: uppercase;\"\u003eSafety Guard\u003c\/span\u003e\n      \u003cspan style=\"font-size: 1.35rem; font-weight: 700; color: #0C1B2A;\"\u003eActive Start Monitor\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1 1 220px;\"\u003e\n      \u003cspan style=\"display: block; font-size: 1rem; font-weight: 800; color: #64748b; text-transform: uppercase;\"\u003eThermal Range\u003c\/span\u003e\n      \u003cspan style=\"font-size: 1.35rem; font-weight: 700; color: #0C1B2A;\"\u003e2x Up to 1,200°C\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section: Power \u0026 Ordering Configurations (3 Column Grid) --\u003e\n  \u003ch3 style=\"font-size: 1.55rem; color: #0C1B2A; text-transform: uppercase; letter-spacing: 1px; margin-bottom: 0.75rem; font-weight: 700;\"\u003e\n    Power Options \u0026amp; Custom Cable Setup\n  \u003c\/h3\u003e\n  \u003cp style=\"font-size: 1.25rem; color: #475569; margin: 0 0 2rem 0;\"\u003e\n    Select the hardware format that matches your paramotor starting and electrical setup:\n  \u003c\/p\u003e\n\n  \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(320px, 1fr)); gap: 1.75rem; margin-bottom: 3rem;\"\u003e\n    \n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 5px solid #0C1B2A;\"\u003e\n      \u003cspan style=\"font-size: 0.85rem; font-weight: 800; color: #0C1B2A; text-transform: uppercase; letter-spacing: 1px;\"\u003eOption 01\u003c\/span\u003e\n      \u003ch4 style=\"margin: 0.35rem 0 0.75rem 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eDirect DC (Electric-Start)\u003c\/h4\u003e\n      \u003cp style=\"margin: 0; font-size: 1.15rem; color: #334155; line-height: 1.7;\"\u003e\n        Supplied without an external battery pack for paramotors equipped with electric starters and a 12 V battery. Operates across 5–20 V DC, waking automatically via the RPM sensor when the engine fires up or manually via the ENT button. Tracks live bus voltage with min\/max alarms.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 5px solid #0C1B2A;\"\u003e\n      \u003cspan style=\"font-size: 0.85rem; font-weight: 800; color: #0C1B2A; text-transform: uppercase; letter-spacing: 1px;\"\u003eOption 02\u003c\/span\u003e\n      \u003ch4 style=\"margin: 0.35rem 0 0.75rem 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eWith AAA Battery Box\u003c\/h4\u003e\n      \u003cp style=\"margin: 0; font-size: 1.15rem; color: #334155; line-height: 1.7;\"\u003e\n        Supplied complete with an external AAA battery box (63 × 48 × 15 mm). Engineered for manual pull-start engines (such as Vittorazi Moster 185 Manual, Atom 80, EOS, and Top 80). Includes a programmable Auto-Off timer (up to 250 minutes) to prevent battery drain after flight.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 5px solid #0C1B2A;\"\u003e\n      \u003cspan style=\"font-size: 0.85rem; font-weight: 800; color: #0C1B2A; text-transform: uppercase; letter-spacing: 1px;\"\u003eOption 03\u003c\/span\u003e\n      \u003ch4 style=\"margin: 0.35rem 0 0.75rem 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eCustom Cable Lengths\u003c\/h4\u003e\n      \u003cp style=\"margin: 0; font-size: 1.15rem; color: #334155; line-height: 1.7;\"\u003e\n        Supplied standard with a 130 cm thin digital interconnect cable between the display and engine sensing hub. Custom cable lengths can be specified upon order to suit tight competition cages (avoiding excess wire weight) or tandem trike frames requiring extended routing.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- Section: Start Monitor Safety System Deep Dive --\u003e\n  \u003cdiv style=\"background-color: #f8fafc; border: 1px solid #cbd5e1; border-left: 6px solid #0C1B2A; border-radius: 8px; padding: 2.25rem; margin-bottom: 3rem;\"\u003e\n    \u003ch3 style=\"font-size: 1.5rem; color: #0C1B2A; text-transform: uppercase; letter-spacing: 0.8px; margin: 0 0 1.25rem 0; font-weight: 700;\"\u003e\n      Start Monitor System: Active Runaway Prevention\n    \u003c\/h3\u003e\n    \u003cp style=\"font-size: 1.2rem; color: #334155; margin: 0 0 1.25rem 0; line-height: 1.8;\"\u003e\n      Accidental full-throttle surges during ground starting can lead to serious injuries and prop strikes. The Fly Henry PPG Meter features an automated electronic interlock wired directly to your engine kill switch:\n    \u003c\/p\u003e\n    \u003cul style=\"margin: 0; padding-left: 1.6rem; color: #334155; font-size: 1.2rem; line-height: 1.85;\"\u003e\n      \u003cli style=\"margin-bottom: 0.75rem;\"\u003e\n\u003cstrong\u003eAutomatic Engine Kill:\u003c\/strong\u003e If the engine exceeds your set \u003cem\u003eRevolution Limit\u003c\/em\u003e during startup within the designated \u003cem\u003eTime Limit\u003c\/em\u003e, the PPG Meter grounds the ignition for your selected \u003cem\u003eAlarm Time\u003c\/em\u003e, cutting the engine immediately.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 0.75rem;\"\u003e\n\u003cstrong\u003e\"Just Once\" In-Flight Restart Mode:\u003c\/strong\u003e Arms the safety cut-off exclusively during the first ground start after boot-up. If the engine starts normally, the runaway cut-off automatically disarms for subsequent restarts—allowing thermal pilots to turn off their engines in flight and restart with immediate full power.\u003c\/li\u003e\n      \u003cli style=\"margin-bottom: 0;\"\u003e\n\u003cstrong\u003e\"Always Enabled\" Mode:\u003c\/strong\u003e Keeps the startup protection active every time the engine comes to a stop, providing continuous ground safety for routine flight operations.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Section: Core Capabilities (2x2 Grid) --\u003e\n  \u003ch3 style=\"font-size: 1.55rem; color: #0C1B2A; text-transform: uppercase; letter-spacing: 1px; margin-bottom: 0.75rem; font-weight: 700;\"\u003e\n    Flight \u0026amp; Engine Telemetry Functions\n  \u003c\/h3\u003e\n  \u003cp style=\"font-size: 1.25rem; color: #475569; margin: 0 0 2rem 0;\"\u003e\n    Comprehensive diagnostic oversight in a compact, vibration-isolated package:\n  \u003c\/p\u003e\n\n  \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(320px, 1fr)); gap: 1.75rem; margin-bottom: 3rem;\"\u003e\n    \n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 4px solid #0C1B2A;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.85rem;\"\u003e\n        \u003cspan style=\"background: #0C1B2A; color: #ffffff; width: 32px; height: 32px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-size: 0.95rem; font-weight: 700; margin-right: 12px;\"\u003e01\u003c\/span\u003e\n        \u003ch4 style=\"margin: 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eDual 1,200°C Thermal Array\u003c\/h4\u003e\n      \u003c\/div\u003e\n      \u003cp style=\"margin: 0; font-size: 1.18rem; color: #334155; line-height: 1.75;\"\u003e\n        Monitors up to 2 high-temperature channels (configurable for CHT under-spark-plug rings or threaded exhaust EGT probes) up to 1,200°C (2,192°F) with independent warning thresholds.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 4px solid #0C1B2A;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.85rem;\"\u003e\n        \u003cspan style=\"background: #0C1B2A; color: #ffffff; width: 32px; height: 32px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-size: 0.95rem; font-weight: 700; margin-right: 12px;\"\u003e02\u003c\/span\u003e\n        \u003ch4 style=\"margin: 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eInductive RPM Sensing\u003c\/h4\u003e\n      \u003c\/div\u003e\n      \u003cp style=\"margin: 0; font-size: 1.18rem; color: #334155; line-height: 1.75;\"\u003e\n        Senses engine speed by wrapping a dedicated lead 4 to 6 turns around the spark plug HT ignition cable. Compatible with 0.5, 1, or 2 pulses per revolution, with customizable overspeed alarms.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 4px solid #0C1B2A;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.85rem;\"\u003e\n        \u003cspan style=\"background: #0C1B2A; color: #ffffff; width: 32px; height: 32px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-size: 0.95rem; font-weight: 700; margin-right: 12px;\"\u003e03\u003c\/span\u003e\n        \u003ch4 style=\"margin: 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003eFuel Tracking \u0026amp; Leak Alarm\u003c\/h4\u003e\n      \u003c\/div\u003e\n      \u003cp style=\"margin: 0; font-size: 1.18rem; color: #334155; line-height: 1.75;\"\u003e\n        Supports 3-point tank level calibration (0%, 50%, 100%) to calculate remaining flight airtime. With an optional flow sensor, it tracks live consumption and triggers alarms if fuel flow spikes abnormally.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"border: 1px solid #cbd5e1; border-radius: 8px; padding: 1.75rem; background: #ffffff; border-top: 4px solid #0C1B2A;\"\u003e\n      \u003cdiv style=\"display: flex; align-items: center; margin-bottom: 0.85rem;\"\u003e\n        \u003cspan style=\"background: #0C1B2A; color: #ffffff; width: 32px; height: 32px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; font-size: 0.95rem; font-weight: 700; margin-right: 12px;\"\u003e04\u003c\/span\u003e\n        \u003ch4 style=\"margin: 0; font-size: 1.35rem; color: #0C1B2A; font-weight: 700;\"\u003ePIN-Secured Timers\u003c\/h4\u003e\n      \u003c\/div\u003e\n      \u003cp style=\"margin: 0; font-size: 1.18rem; color: #334155; line-height: 1.75;\"\u003e\n        Tracks four distinct engine times: an overall cumulative Hobbs meter (lockable via a 4-digit security PIN to prevent resets), two user trip counters, and a maintenance countdown timer.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003chr style=\"border: 0; border-top: 1px solid #cbd5e1; margin: 3.5rem 0;\"\u003e\n\n  \u003c!-- Technical Specifications Table --\u003e\n  \u003ch3 style=\"font-size: 1.55rem; color: #0C1B2A; text-transform: uppercase; letter-spacing: 1px; margin-bottom: 2rem; display: flex; align-items: center; font-weight: 700;\"\u003e\n    \u003cspan style=\"display: inline-block; width: 14px; height: 14px; background-color: #0C1B2A; border-radius: 50%; margin-right: 14px;\"\u003e\u003c\/span\u003e\n    Technical Specifications\n  \u003c\/h3\u003e\n  \n  \u003cdiv style=\"overflow-x: auto; border: 1px solid #cbd5e1; border-radius: 8px; margin-bottom: 2.25rem;\"\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 1.2rem; line-height: 1.7;\"\u003e\n      \u003ctbody\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A; width: 44%;\"\u003eOperating Voltage Range\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003e5 V – 20 V DC (or via optional AAA battery box)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eDisplay Module Dimensions\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003e60 mm × 37 mm × 15 mm (Graphic backlit LCD)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eMeasuring Module Dimensions\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003e60 mm × 28 mm × 11 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eOptional Battery Box Dimensions\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003e63 mm × 48 mm × 15 mm (Standard AAA cells)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eStandard Interconnect Cable\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003e130 cm thin data cable (custom lengths available on order)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eTemperature Channels (1 \u0026amp; 2)\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003e2x Inputs: up to 1,200°C (2,192°F) for CHT or EGT probes\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eEngine Speed (RPM) Detection\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eInductive wrap: 4–6 turns around spark plug HT lead\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #f8fafc; border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eStartup Runaway Interlock\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003eIntegrated Start Monitor System (wires directly to engine kill line)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eSupported Engineering Units\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003e°C \/ °F, Litres \/ US Gallons, Percentage\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd style=\"padding: 18px 24px; font-weight: 700; color: #0C1B2A;\"\u003eTarget Aircraft\u003c\/td\u003e\n          \u003ctd style=\"padding: 18px 24px; color: #1e293b;\"\u003ePowered Paragliders (PPG), Paramotor Trikes, and Ultralights (ULL)\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Operational Note Callout --\u003e\n  \u003cdiv style=\"background-color: #f1f5f9; border-left: 6px solid #0C1B2A; padding: 1.75rem 2rem; border-radius: 4px; font-size: 1.18rem; color: #334155; line-height: 1.8;\"\u003e\n    \u003cstrong\u003eInstallation Advisory:\u003c\/strong\u003e The negative power lead must be connected as short as possible directly to the engine case\/skelet. If using the Start Monitor System, wire the dedicated yellow lead into your engine stop button line to allow the safety cut-off to ground the ignition in runaway conditions. The unit powers off manually by holding ESC for 4 seconds.\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Fly Henry","offers":[{"title":"PPG Meter Only","offer_id":58639149334859,"sku":"PPGM","price":240.0,"currency_code":"GBP","in_stock":true},{"title":"PPG Meter w\/ Battery Box","offer_id":58639149367627,"sku":"PPGMB","price":251.0,"currency_code":"GBP","in_stock":true},{"title":"PPG Meter w\/ Battery Box \u0026 Custom Cable Length","offer_id":58639149400395,"sku":"PPGMBC","price":255.0,"currency_code":"GBP","in_stock":true},{"title":"PPG Meter w\/ Custom Cable Length","offer_id":58639149433163,"sku":"PPGC","price":244.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/9719\/6363\/files\/Screenshot_2026-09-29_154759.png?v=1790693292","url":"https:\/\/www.albionaero.co.uk\/products\/ppg-meter","provider":"Albion Aero Services Ltd","version":"1.0","type":"link"}